English Spanish
  Life Medical Equipment
    HomeHome  AboutAbout  ContactContact  Find usFind Us  SearchSearch
Category Listing
 Aesthetic
 Anesthesia
News and Information Blog
 Cardiology
 Defibrillators
 Diapulse Brochure
 Emergency
 Endoscopy
 Imaging
  Bone Densitometers
  C-Arms
  CR
  CT Scanners
  Digitalizers/Scanners
  Gamma Cameras / Nuclear
  Infrared
  Mammography
  Probes
  Processors
  Ultrasound Products
  Ultrasounds
  X-Rays
 Instrumentation
 IV Poles
 Laboratory
 Lamps / Lights
 Medical Furniture
 Miscellaneous
 Neonatal
 Neurology
 OB/GYN
 Ophthalmology
 Packages
 Pain Relief Cream
 Patient Monitoring
 Pediatric
 Physical Therapy
 Pumps
 Respiratory
 Sterilizer
 Surgery
 Survey
 Vascular
 Videos
 Wound Care
 Imaging
Philips  Product Detail
Model: BV25

Features:
    X-ray Source

    • X-ray generator: DC converter-generator

    • X-ray tubes - focal spots: dual focus stationary anode 0.6 and 1.8.

    Fluoroscopy System

    • Image intensifier: 15 cm (6 in) high quantum absorption model with fibre output.

    • TV camera tube: VIDICON with fibre input.

    • Optical coupling between image intensifier and TV camer tube: glass-fibre optics.

    • Source of image distance: 90 cm.

    • Dose rate control: automatic, simultaneous kV/mA control with lock and manual override facilities.

    • KV/mA range: from 0.1mA at 40 kV to 3 mA at 100 kV.

    • Focal spot: 0.6.

    • Grid: Fixed circular grid 44 lines/cm, ration 8, SID=90 cn.

    Collimator

    • Iris diaphragm: electronically controlled iris diagram, automatically limited to size of image intensifier input field (15 cm 0). Remotely controlled and steplessly adjustable to a field size of 5 cm diameter at input field image intensifier.

    • Shutters: two parallel shutters of 0.5 mm Cu, remotely controlled and steplessly adjustable for a field of 1 to 16 cm wide at image intensifier. The shutters can be rotated +/- 90 degrees; in the mid position, the slit aperture is perpedicular to the length of the generator housing.

    TV System

    • XTV 5 50 Hz: 625 lines

    • 60 Hz: 525 lines.

    • Bandwith: 15 MHz.

    • Control: AGC feedback to dose rate control system.

    • Video monitor(s): 51 cm (20") screen motorized, remotely controlled image rotation and reversal.

    • Output signal for recording system: output level of the composite signal always 1.0 Vp-p positive across 75 ohms.

    • Measuring field selection for adapting control mode to the objects to be examined:

      • Small measuring field: 0.3 x diameter of TV image, e.g. extremities.
      • Intermediate measuring field: 0.5 x diameter of TV image, e.g. bile duct and gall bladder.
      • The measuring field is selected automatically as a function of the kV used.


    C-Arm Movements

    • Height adjustments: 50 cm, motorized.

    • Horizontal movement: 20 cm.

    • Scanning in horizontal plane: 12 1/2 degrees to either side.

    • Rotation of c-arm: 205 degrees in either direction.

    • Orbital movement of c-arm: 115 degrees.

    • Distance between x-ray tube space and image intensifier with 30 cm spacer: 60 cm.

    Radiography

    • Tube current: fixed, 20 mA.

    • Tube voltage: adjustable in steps of 5kV from 40 to 100 kv.

    • Exposure time: adjustable in steps of 10 ms to 4.0 s (mAs is displayed).

    • Focus: 1.8.

    • Radiography parameter display: digital disply of tube voltage (kV) and exposure time/current product (mAs).

    • Collimator: if iris diaphragm was set to less than 15 cm during fluoroscopy, this remains so unless cancelled. Circular fields of 15 or 24 cm can be selected by remote control.

    • Rotatable cassette holder: suitable for cassette and grid cassettes of 24 x 24 cm.

    • Proffered grid: ratio 10.44 lines/cm, SID = 90 cm.

    • Inherent filtration: 3 mm Al at 75 kV.

    • Leakage radiation factor: 100 kVdc, 0.06 mA (2160 mAs/hr)

    Accuracy of Display

    • Fluoroscopy: voltage deviation +/- 6% +/- 2kV, current deviation +/- 7 % +/- 0.02 mA.

    • Radiography: volatage deviation +/- 10%, current deviation +/- 10 %, time deviation +/- 2 ms +/- 3%, mAs product deviation +/- 12 % +/- 0.4 mAs.

    Weight

    • C-arm stand: 210 kg.

    • Monitor trolley excluding image memory single monitor: 131 kg

    • With dual monitors: 164 kg.

    Mains Supply

    • Voltage: 110/120/127/190/208/220/240 V single phase, +/- 10%.

    • Frequency: 50/60 Hz.

    • Earth leakage current: less than 100 uA.


Request Info


Enlarged Picture
 


Back



Join the Life Medical Equipment mailing list
Email:

 7874 NW 64th Street,  Miami, Florida, 33166
Tel: (305) 594-0000 - Fax: (305) 594-2020 -