English Spanish
  Life Medical Equipment
    HomeHome  AboutAbout  ContactContact  Find usFind Us  SearchSearch
Category Listing
 Aesthetic
 Anesthesia
News and Information Blog
 Cardiology
 Defibrillators
 Diapulse Brochure
 Emergency
 Endoscopy
 Imaging
  Bone Densitometers
  C-Arms
  CR
  CT Scanners
  Digitalizers/Scanners
  Gamma Cameras / Nuclear
  Infrared
  Mammography
  Probes
  Processors
  Ultrasound Products
  Ultrasounds
  X-Rays
 Instrumentation
 IV Poles
 Laboratory
 Lamps / Lights
 Medical Furniture
 Miscellaneous
 Neonatal
 Neurology
 OB/GYN
 Ophthalmology
 Packages
 Pain Relief Cream
 Patient Monitoring
 Pediatric
 Physical Therapy
 Pumps
 Respiratory
 Sterilizer
 Surgery
 Survey
 Vascular
 Videos
 Wound Care
 Imaging
OEC Diasonics  Product Detail
Model: DXR-5

  • 1986 Model

  • 6" Image Intensifier - upgraded 1996

  • CCD camera model ISI-7000

  • Double monitors

Specifications:
  • Input Power

    • Line voltage:

      • 208 / 220 / 240 VAC +/- 5%, 30 A, (60 A peak), 60 Hz (50 Hz optional).

      • 104 / 110 / 120 VAC +/- 5%, 30 A, (50 A peak), 60 Hz (50 Hz optional). 1.0 mm focal spot size / 100 mA disabled

    • Radiographic peak power demand: 12 kVa at maximum exposure (100 kVp / 100 mA)

    • Fluoroscopic power demand: 1200 watts maximum

    • Standby power: 500 watts maximum

    • Line regulation: 8% at maximum radiographic exposure

  • High Voltage Generator

    • Output:

      • Full wave, chassis mounted.

      • 125 kVp, 10 mA continuous (100 mA for 10 seconds at 10% duty cycle).

  • X-ray Source Assembly

    • Focal spot: Dual, 0.3 mm and 1.0 mm

    • Filtration: 2.5 mm total aluminum equivalent

    • Anode heat storage capacity: 300,000 HU

    • Housing heat storage capacity: 1,200,000 HU

    • Beam limiting device technique leakage factors: 120 kVp and 4.7 mA

  • Fluoroscopy

    • Focal spot size: 0.3 mm

    • High volatage range: 40 kVp to 120 kVp

    • Current range:

      • Normal: 0.5 mA to 5.0 mA

      • Boost Mode: 20 mA maximum

    • Collimation:

        Maximum diameter circle: 10 inches (25.4 cm), or 9 inches (22.8 cm), or 6 inches (15.2 cm) continuously adjustable to less than 5 x 5 cm.

    • Pulse time selection: 0.4 to 0.9 seconds

    • One-shot timer selection: 0.4 to 0.9 seconds

  • Radiography

    • 0.3 mm focal spot:

      • High voltage range: 50 kVp to 120 kVp

      • mAs range: 3 mAs to 200 mAs

    • 1.0 mm focal spot:

      • High voltage range: 50 kVp to 120 kVp

      • mAs range: 25 mAs to 500 mAs.

    • Neo-Natal

      • High voltage range: 50 kVp to 90 kVp

      • mAs range: 1 mAs to 5 mAs (recommended maximum)

    • Collimation:

      • Maximum diameter circle: 10 inches (25.4 cm), or 9 inches (22.8 cm), or 6 inches (15.2 cm) continuously adjustable to less than 5 x 5 cm.

  • Accuracy:

    • Radiographic / Fluoroscopic

      • kV: +/- 8% or +/- 3 kVp, which ever is greater

      • mAs: +/- 8% or +/- 3 mAs, which ever is greater

    • Neo-Natal (radiographic)

      • kV: +/- 12% or +/- 5 kVp, which ever is greater

      • mAs: +/- 8% or +/- 3 mAs, which ever is greater

    • Fluoroscopic only

      • mA: +/- 8% or +/- 3 mAs, which ever is greater

  • Cassette Holder: (film)

    • 10 x 12" x 5/8" nominal

    • 24 cm x 30 cm metric

  • Image Intensifier (6")

    • Input screen diameter: 6" (15 cm)

    • Resolution: Better than 42 line pairs/cm central and better than 40 line pairs/cm peripheral.

    • Contrast ratio: 14:1 minimum, 18:1 typical

    • Low frequency contrast (LFC): 15:1 typical

    • Contrast sensitivity: 1.75 % minimum

  • Image Intensifier (6"/9" Dual mode)

    • Input screen diameter: 8.5" (215 mm +/ 5 mm)

    • Resolution: Better than 40 line pairs/cm central and better than 36 line pairs/cm peripheral.

    • Contrast ratio: 14:1 minimum, 18:1 typical

    • Low frequency contrast (LFC): 22:1 typical

    • Contrast sensitivity: 1.75% minimum

  • TV Camera

    • Rotation: 360 degrees, motorized

    • Video output: Composite video, EIA RS170

  • Video Image Storage

    • Systems equipped with hard disk - 60 images.

  • Video Monitors

    • Cathode ray tube:

      • Size: 15-inch diagonal

      • Coating: P4/104 phosphor (monochrome)

      • Protection: T-band implosion

      • Resolution: 800 lines minimum at center

      • Geometric Distortion: Less than 2% of active raster height

    • Video bandwidth: Greater than 15 Mhz at -3dB

    • Input impedance: 75 ohm terminated

    • Input signal: RS170 standard, negative sync.

  • Video Output

    • #1 (Left video)

      • Normal: Left monitor video processed through digital circuitry

      • Bypass: Direct video output from camera (unprocessed)

    • #2 (Right Video)

      • Right monitor, processed video

    • VTR (on systems equipped with this feature): Direct video output from camera

  • Mechanical Space / Movement

    • Free space in arc:

      • With skin spacer installed: 26.75" (66.7 cm)

      • With skin spacer removed: 30" (76.2 cm)

    • Depth of arc: 22.7" (57.7 cm)

    • Arc movement: 90 degrees

    • Left / right scan movement: +/- 15 degrees

    • Vertical travel: 18" (45.7 cm) motorized

    • Horizontal travel: 8" (20.3 cm)

    • Arm rotation: Fully motorized, 345 degree minimum

    • Reversible C-arm: Manual flip-flop

  • Environmental Requirements

    • Ambient temperature:

      • Operating: 5 to 40 degrees C

      • Storage: 5 to 55 degrees C

    • Altitude: 10,000 ft. maximum

    • Humidity: 0 to 90%, non-condensing

  • Dimensions

    • Main frame (in storage position): 78" L x 70" H x 35 1/2" D (198.1 cm x 177.8 cm x 91.2 cm)

    • Monitor cart: 60" H x 32" W x 26" D (152.4 cm x 81.3 cm x 66 cm)

  • Weight

    • Main frame: 800 lbs (360 kg) approximate

    • Monitor cart: 360 lbs (162 kg) approximate