Viasys Micro Spirometer Product Detail
The Micro Spirometer is specifically designed for situations where low cost precision respiratory measurement is required. Selected for heart-lung transplant programmes world-wide as well as for major clinical trials. This spirometer has proven (see bib. No.1 below) long-term accuracy and reliability together with the endorsement of a British Design Award.
Low end-expiratory flows are often seen in COPD and Asthmatic patients. Micro Medical has developed a Gold Standard Transducer to ensure that such measurements are absolutely precise, and many other spirometers cannot offer this.
The Micro Spirometer will measure and display on it's high visibility screen FEV1 and FVC. Simple to use, lightweight and with over 50,000 units in use around the world, these instruments are the World's No.1 spirometers.
Specification:
Measurement: Micro FEV1 and FVC
Volume Range: 0.1 to 9.99 Litres
Flow Range: 0.2 to 15.00 Litres/Second
Accuracy: ± 3%(meets, and exceeds all known spirometry performance standards)
Dimensions: 170x60x26mm
Weight Net: 190gm (unit)
Weight Packed: 625gm
Power Supply: Single 9 volt PP3
PulmoLife is a new COPD screening device, designed for quick and easy screening of adult smokers for early detection of COPD.
A COPD screening device reporting FEV1 and 'Lung Age'
PulmoLife is a new COPD screening device, designed for quick and easy screening of adult smokers for early detection of COPD. Smokers are at the greatest risk of developing COPD and decline in lung function in susceptible smokers has been shown to be twice that of non-smokers.
This small, innovative device measures FEV1, the measurement of choice in COPD screening. The unit will display a patient's result together with the FEV1 as a percentage of their predicted value. These results are used to calculate a 'Lung Age'. The associated 'Lung Age' graphical display may help the patient realise the physical damage caused by smoking, encouraging attendance for smoking cessation advice and full spirometry assessment, leading to early diagnosis and appropriate management of COPD
Suitable for
FEV1 testing programs
Identification of early signs of COPD in smokers over 40 or anyone with symptoms
Helping susceptible smokers to quit
FEV1 and FEV1% predicted
Forced Expiratory Volume in the First Second of Expiration. The use of FEV1 is well documented as a useful diagnostic tool for the detection of early COPD. When comparing its result against predicted values and using patients FEV1 result as a percentage of predicted values (FEV1% predicted) the likelihood and severity of COPD can be seen.
'Lung Age'
In addition to comparing patients FEV1 results with the predicted reference values for normal subjects, estimation of 'Lung Age' can be used to demonstrate to smokers the damage caused to their lungs by smoking in a way they can understand. The 'Lung Age' estimation is based on a patients FEV1 results and predicted values. A 'Lung Age' example; a 40 year old 5'9" (1.75m) male smoker has an FEV1 of 3.4L giving an estimated 'Lung Age' of 52 years. This is because the FEV1 is 100% of the predicted value that a 52 year old would be expected to get.
Features:
Measures FEV1 - the measurement of choice in COPD screening
Gives FEV1 result as a percentage of predicted values
'Lung Age' Interpretation (Morris and Temple)
Used as a motivational tool for smoking cessation
Specifications:
Transducer: Digital Volume Transducer
Resolution: 0.01L
Accuracy: +/-3% (meets, and exceeds all known spirometry performance standards)
Volume Range: 0 - 8 Litres
Flow Range: 0-14 Litres/Second
Predicted Values: 1) ECCS 2) NHANES III 3) Asian (Chinese)
Display: Custom Liquid Crystal
Power Supply: 3V Lithium Ion Coin Cell Battery
Dimensions: 131 x 59 x 38 mm
Weight: Unit only: 96g Unit complete with accessories: 226g