Sechrist Product Detail
Model: Millennium
From Sechrist Industries comes the Millennium; - the infant / pediatric ventilator for the next century. Designed for maximum performance and user-friendly convenience, for which Sechrist has always been known. The Millennium; combines state-of-the-art electronics with the simplicity of pressure sensing technology. The result: simple, reliable ventilation for all your neonatal, infant, and pediatric patient requirements.
Reliable, Versatile, Simple. Just by looking at the Millennium; you can tell how easy it is to use. Ventilation modes such as SIMV/IMV, Assist Control, and Backup ventilation in CPAP make the Millennium; the optimal choice in basic, reliable neonatal, infant and pediatric ventilation.
Synchronization for even the smallest child. What sets the Millennium; apart is the patented SmartSync™, a unique pressure sensing device that synchronizes the patient's natural breathing cycle with the ventilator. It has a maximum sensitivity of 0.10 cmH20, and a response time of 5-40 milliseconds depending upon the sensitivity settings. With this technology from a company you've known and trusted for decades, you can be certain the Millennium; will provide your patients with unparalleled performance.
Specifications:
- Recommended Applications: Neonatal, infant& pediatric patients < 50 Kg
- Flow: 2-32 lpm; flush 40 lpm
- Modes of operation: AC, SIMV/IMV, CPAP, CPAP with backup ventilation, Standby
- Inspiratory Time: 0.1 to 3.0 seconds
- I:E Ratio:
- Normal Range: 1:1.0 to 1:10 (sens. off), 1:1.0 to 1:99 (sens. on).
- Inverse Range: 1.0:1 to 4.0:1
- Rate: 2 to 150 breaths per minute
- Expiratory Pressure: 0 to 20 cmH2O
- Inspiratory Pressure: 5 to 70 cmH2O
- Waveform: Tappered to square
- Manual Breath: Electronically controlled, based upon the inspiratory pressure, inspiratory time and waveform control setting
- Alarms:
- High Inspiratory Pressure
- Low/Prolonged Inspiratory Pressure
- Low PEEP/Baseline Pressure
- Apnea
- High Respiratory Rate
- Loss/Low Electrical Power
- System Error/Vent Inop
- Loss of Inlet Gas
- Alarm Delay: 3 to 15 seconds
- Alarm Mute: 30 Seconds
- Safety Pressure Relief Valve: 15 to 85 cmH20
- Indicators:
- Inspiratory Pressure
- PEEP/Baseline Pressure
- Calculated I:E Ratio
- Mean Airway Pressure
- Proximal Airway Pressure Bar Graph
- Measured Respiratory Rate
- Dimensions: 13.5"(34.29cm)H 11"(27.94cm)W 9.5"(24.13cm)D
- Weight: 21 lbs (9.5kg)
- Gas Consumption: 14 lpm above the continuous flow setting
- Power Requirements:
- 110 to 120 VAC, 50/60 Hz
- 220 to 240 VAC, 50/60 Hz
- 100 VAC, 50/60 Hz
Request Info
|