English
Spanish
Home
About
Contact
Find Us
Search
Category Listing
Aesthetic
Anesthesia
Blog
Cardiology
Defibrillators
Diapulse Brochure
Emergency
Endoscopy
Imaging
Instrumentation
IV Poles
Laboratory
Lamps / Lights
Medical Furniture
Miscellaneous
Neonatal
Neurology
OB/GYN
Colposcopes
Curettage
Fetal / Maternal Monitors
Specula
Ophthalmology
Packages
Pain Relief Cream
Patient Monitoring
Pediatric
Physical Therapy
Pumps
Respiratory
Sterilizer
Surgery
Survey
Vascular
Videos
Wound Care
OB/GYN
Corometrics Product Detail
Model: 116
Features:
Toco, Ultrasound Transducer and ECG
Dual heart rate (twins or maternal/fetal), autocorrelation, and high resolution recorder.
Provides clean accurate ultrasound and uterine activity tracings.
Data storage and transmission.
Built-in high density dot matrix printer.
Specifications:
Direct ECG:
Technique: peak detecting beat-to-beat cardiotachometer
Heart rate counting range: 30-240 BPM
Heart rate resolution: +/-1 BPM
Artifact elimination: Switch selectable +/-25 BPM artifact rejection.
Input signal range differential: 15 microvolt to 2 millivolt peak-to-peak (fetal), 100 microvolt to 2 millivolt peak-to-peak (maternal)
Common mode: 20 VDC (max)
Preamplifier bandwith: 1.0 Hz to 100 Hz
Common mode rejection:>120 dB balance
With patient cable: >110 dB 5k RA or unbalance.
Input equivalent noise: < 10 microvolt at 120 VAC.
Isolation mains to patient connection: > 2 kV.
Leg plate tester: Simulated r-wave at 120 +/- 1 BPM
Ultrasound:
Technique: pulsed doppler with autocorrelation processing
Pulse repetition frequency: 4kHz in single ultrasound mode, 2kHz in dual ultrasound mode
Pulse duration: 92 microseconds
Center frequency: 1.151 MHz.
Intensity: <10mW/cm2
Heart rate counting range: 50-210 BPM
Leakage current: <10 microA at 120 VAC
Pressure:
Range: 0-100 mmHg
Tocotransducer: 0-100 relative units (0-120 grams)
Excitation voltage: +4.0 VDC
Resolution: 1 mmHg
Bandwidth: TOCO Transducer DC to 0.5 Hz, strain gauge DC to 3 Hz
Zero temperature drift: <0.1 mmHg/degrees C (electronics only)
Leakage current: <10 microA at 120 VAC (transducer isolated)
Recorder:
Uterine activity: chart width - 4 cm, scaling - 25 mmHg/cm (3.33 kPa/cm), range - 0-100 mmHg, resolution - 1mmHg
Chart drive: speeds: 1,2 and 3 cm/min: accuracy: +/-1%
Heart rate scale:
Domestic - Chart width 7 cm, scaling 30 BPM/cm, range 30-240 BPM, resolution 1 BPM
International - Chart width 8 cm, scaling 20 BPM/cm, range 50-210 BPM, resolution 1 BPM.
Power Requirements and Physical Characteristics:
Voltage: 100 / 120 / 220 / 240 VAC selectable.
Frequency: 50 / 60 Hz
Power consumption: 100 Watts (max.).
Height: 7 in (17.8 cm)
Width: 16.5 in (41.9 cm)
Depth: 17 in (43.2 cm)
Weight: Approximately 34 lbs (15.5 kg)
Request Info
Enlarged Picture
Back
Join the
Life Medical Equipment
mailing list
Email:
7874 NW 64th Street, Miami, Florida, 33166
Tel: (305) 594-0000
- Fax: (305) 594-2020 -
© Copyright 2007 - Life Medical Equipment International Inc.