Corometrics  Product Detail
Model: 116

Features:
  • Toco, Ultrasound Transducer and ECG

  • Dual heart rate (twins or maternal/fetal), autocorrelation, and high resolution recorder.

  • Provides clean accurate ultrasound and uterine activity tracings.

  • Data storage and transmission.

  • Built-in high density dot matrix printer.

Specifications:
  • Direct ECG:

    • Technique: peak detecting beat-to-beat cardiotachometer

    • Heart rate counting range: 30-240 BPM

    • Heart rate resolution: +/-1 BPM

    • Artifact elimination: Switch selectable +/-25 BPM artifact rejection.

    • Input signal range differential: 15 microvolt to 2 millivolt peak-to-peak (fetal), 100 microvolt to 2 millivolt peak-to-peak (maternal)

    • Common mode: 20 VDC (max)

    • Preamplifier bandwith: 1.0 Hz to 100 Hz

    • Common mode rejection:>120 dB balance

    • With patient cable: >110 dB 5k RA or unbalance.

    • Input equivalent noise: < 10 microvolt at 120 VAC.

    • Isolation mains to patient connection: > 2 kV.

    • Leg plate tester: Simulated r-wave at 120 +/- 1 BPM

  • Ultrasound:

    • Technique: pulsed doppler with autocorrelation processing

    • Pulse repetition frequency: 4kHz in single ultrasound mode, 2kHz in dual ultrasound mode

    • Pulse duration: 92 microseconds

    • Center frequency: 1.151 MHz.

    • Intensity: <10mW/cm2

    • Heart rate counting range: 50-210 BPM

    • Leakage current: <10 microA at 120 VAC

  • Pressure:

    • Range: 0-100 mmHg

    • Tocotransducer: 0-100 relative units (0-120 grams)

    • Excitation voltage: +4.0 VDC

    • Resolution: 1 mmHg

    • Bandwidth: TOCO Transducer DC to 0.5 Hz, strain gauge DC to 3 Hz

    • Zero temperature drift: <0.1 mmHg/degrees C (electronics only)

    • Leakage current: <10 microA at 120 VAC (transducer isolated)

  • Recorder:

    • Uterine activity: chart width - 4 cm, scaling - 25 mmHg/cm (3.33 kPa/cm), range - 0-100 mmHg, resolution - 1mmHg

    • Chart drive: speeds: 1,2 and 3 cm/min: accuracy: +/-1%

    • Heart rate scale:

      • Domestic - Chart width 7 cm, scaling 30 BPM/cm, range 30-240 BPM, resolution 1 BPM

      • International - Chart width 8 cm, scaling 20 BPM/cm, range 50-210 BPM, resolution 1 BPM.

  • Power Requirements and Physical Characteristics:

    • Voltage: 100 / 120 / 220 / 240 VAC selectable.

    • Frequency: 50 / 60 Hz

    • Power consumption: 100 Watts (max.).

    • Height: 7 in (17.8 cm)

    • Width: 16.5 in (41.9 cm)

    • Depth: 17 in (43.2 cm)

    • Weight: Approximately 34 lbs (15.5 kg)