Model: HKN-93A
Features:
Servo control: Skin temp of baby, air temp of bed
Automatic control or manual control selectable
Light touch control panel waterproof
Apgar timer including in controller
Heating consumption: 0-100%
Four alarm identification
Radiate Box adjustable in tow direction from 0-90 degrees
Bassinet gradient adjustable in +/- 15 degree angle
X-ray tray under bassinet, convenient for taking x-ray photo
Specifications:
Power Supply Requirements
Voltage: 220 V +/- 10%, 50 Hz +/-10%, 110V +/- 10%, 60 Hz +/- 2%
Power Rate: ≤ 1200va
Operating Condition
Environment temperature: 18-30 degrees Celsius
Relative Humidity: < 80%
Environment air flow speed: <0.3 m/s
Temperature Control
Bed Temperature Control Range: 25 - 37 degrees Celsius
Skin Temperature Control Range: 34 - 37 degrees Celsius
Temperature control accuracy: +/- 0.1 degrees Celsius
Measure temperature error: ≤ +/- 0.3 degrees Celsius
Mattress temperature uniformity: ≤ 2.0 degrees Celsius
Temperature rise time: ≤ 38 minutes
Other Parameter and Physical Data
Far-infrared wavelenght: 1 - 3 um
Apgar timer: Continues record time and audible alarm every 1, 5, 10 minutes
Radiator horizon angle: 0, 30, 60 degree two ways adjustable
Bassinet Tilt Angle Adjustable: +/- 15 degrees
Mattress Tray Dimensions: 750 mm x 585 mm
Bassinet Max Load: 10 Kg
Instrument Shelf Max Load: 2 Kg
IV Pole Max Load: 2 Kg
Height from ground to radiator: 180cm
Height from ground to bed: 85 cm
Packing size: 127 cm x 81 cm x 103 cm Main Body, 77.5 cm x 34.8 cm x 42 cm Accessories HKN-93A
Gross Weight: 10 Kg HKN-93
Four Kind Failures, Alarm Identification (Audible and Visible) When alarm activates, automatic cut off power supply and display actual temperature
Over Temperature Alarm: Activated actual temperature exceeds 38 degrees Celsius
Temperature Deviation Alarm: Activated actual temperature 1 degrees Celsius departure the set point
Sensor Alarm: Activated if sensor short circuit, open circuit or place out of right position
Power failure alarm: Activated if power break down or power cord disconnect when turn on the unit
HKN-93A Infant Warmer - Based on HKN 93 Infant Warmer equipped with:
HF-1 resuscitator
S-I suction unit
Oxygen therapy including: oxygen cylinder 2 pcs, oxygen aspirator, oxygen flow meter, oxygen valve.
TJ-1 Baby head frame
With phototherapy lamps for neonate jaundice (6 lamps)