Model: TI-100

Features:
  • Intended for transport of high risk, premature, low birth-weight, or critically ill newborns.

  • It provides a means to control air temperature, oxygen concentrations, and relative humidity.

  • A doubled wall hood permits full visibility and provides an effective thermal barrier from the environment.

Specifications:
  • Power Requirements

      AC: 110 / 120 VAC 50 / 60 / 400 Hz, sine or square wave 170 / 200 Watts and 225 / 270 Watts with batteries charging.

      DC: 12 VDC, 115 Watts

    • Internal Battery

        Type: get type, sealed and rechargeable.

        Voltage: 12 VDC nominal.

        Quantity: 2.

        Charging time: Two batteries take 20 minutes to recharge from fully discharged.

        Life expectancy: Minimum 200 full charge/discharge cycles.


    • Chassis Leakage Current: 100 uA or less

    • Alarms:

        High Temp: Actuates at displayed incubator temperature of 39 degrees, plus or minus 0.5 degrees Celsius.

        Sensor: Actuates if High Temp alarm sensor is electrically open or shorted.

        Power Failure: Actuates if main AC power fails and no DC back-up power is present.

        Heater Temp: Actuates if heater temperature exceeds 77 degrees Celsius nominal.

        Low DC: Actuates if incubator DC voltage has fallen below 10.5 VDC nominal.


    • Temperature Set Point Range: 21.5 degrees Celsius plus or minus to 38 degrees Celsius.

    • Temperature Rise Time: 30 minutes.

    • Temperature Variability: 0.2 degrees Celsius.

    • Temperature Overshoot: 1.5 degrees Celsius maximum.

    • Temperature Uniformity: 1 degree Celsius.

    • Correlation of Displayed Incubator to Actual Incubator Temperature at Temperature Equilibrium: 1 degree Celsius.

    • Correlation of Displayed Incubator Temperature to Set Point at Temperature Equilibrium: Plus or minus 0.5 degrees Celsius.

    • Observation Light Output: 10-foot candles at mattress level.

    • Dimensions:

        Length - 102 cm (40.25").

        Width - 56.5 cm (22.25").

        Height - 118.7 cm (46.75") maximum, 88.3 cm (34.75") minimum.


    • Weight: 86.7 kg (191 kg) including hood, stand and batteries.