Model: C-300

Features:
  • The forced air circulation system permits stable temperature control, uniform heat distribution, humidification, and effective isolation of the infant from airborne contaminants.

  • The unit provides a connection for the administration of supplemental oxygen.

  • Power Requirements:

    • Model C300-2: 110/120V~; 50/60 Hz, 175/205 W.

    • Model C300-2E: 220/240V~; 50/60 Hz, 175/205W.

  • Chasis Leakage Current: 100 uA or less.

  • Alarms:

    • Sensor: actuates if high temperature alarm sensor is electrically open or shorted.

    • High Temperature: Activates if incubator display reads 38.5C +/- 0.5C.

    • Power Failure: Activates if main AC power fails and no DC back-up power is present.

    • Heater Temperature: Activates if heater temperature exceeds 77C (nominal).

    • Alarm Reset switch: Cancels Alarm indicators if alarm condition has been corrected (except power failure alarm).

  • Temperature Set Point Range: 22.0 +/- 0.5C to 38.0 +/- 0.1C

  • Temperature Rise Time: 45 minutes

  • Temperature Variability: 0.2C

  • Temperature Overshoot: 1.5C maximum

  • Correlation of Displayed Incubator Temperature to Actual Incubator Temperature at Temperature Equilibrium: +/- 1 C.

  • Correlation of Displayed Incubator Temperature to Set Point at Temperature Equilibrium: 0.5C

  • Oxygen Concentration Range: 21% to at least 58 % at 6 LPM flow rate

  • Humidity: Typically between 50% and 70%

  • Air Velocity Over Mattress: Does not exceed < 20cm/sec (40 ft/min)

  • Ambient Operating Temperature: 21C to 28C.

  • Noise Level within Hood: 60 dBA maximum with 50 dBA or less ambient. 80 dBA maximum during alarm.

  • Nominal Dimensions:

    • Without stand - Height: 60.3 cm (23.75 in) Width: 52.7 cm (20.75 in) Length: 81.3 cm (32 in).

    • With stand - Height: 128.9 cm (50.75 in) Width: 55.9 cm (22 in), length: 81.3 cm (32 in).

  • Nominal Weight:

    • Without stand: 36.4 kg (80 lbs)

    • With Stand: 54.5 kg (120 lbs)