Model: INC-LME-TI20

Features:
  • Air-temp or skin-temp, servo controlled by Micro-process

  • Automatic adjust power supply AC / DC or ambulance power supply

  • With isolated alarm system, it will be automatic running as soon as the normal alarm system broken

  • With specially connector for ambulance power supply.

  • With super long trolley for assembly necessary medical device (patient monitor, infusion pump, etc.)

  • Six quiet operate iris port

  • Heating power rate 0-100%

  • Double wall prevent heat losing

  • The access panel can open in two side for draw out the bassinet from hood.

  • The chamber hood can whole move, convenient for any rescue operating.

  • Gradient of the bassinet can be adjusted in two step

  • Trolley stand can pucker, and suitable for ambulance delivery.

Standard Accessories:
  • Trolley stand puckerable

  • IV Pole

  • Skin Sensor

  • Air Filter

  • Mattress

  • Safe keep belt

  • Iris port cover

  • Battery free maintenance

  • Fuse 2.5A

  • Power cord

  • Operator manual

  • Installation tools

Specifications:
  • Power Supply

    • AC: AC110V~230V, 50Hz~60Hz, 200VA max. or less

    • DC: DC12V, 150VA max or less, DV24V, 150VA or less

      • Normal: <0.5mA

      • Single Fault State: <1mA

      • According to IEC601-1, the unit is class I, BF type, internal power supply unit.

  • Internal Battery

    • Type: Topin TP12-26 Battery

    • Quantity: 2

    • Voltage: 12V / 26 AH

    • Charge Time (from full discarge):

    • One battery: 12 hours

    • Two battery: 24 hours

    • Life Expectancy: 200 complete charge / discharge cycles

    • Work time at temperature equilibrium: 45 min (1 battery). 90 min (2 batteries)

    • Battery's length: 17.5 cm

    • Battery's width: 16.6 cm

    • Battery's height: 12.6 cm

    • Battery's weight: 9.1 kg

  • Ambient temperature (Normal)

    • Operating range (limited): 0-40° C

    • Storage range: 40 - 70° C

  • Ambient humidity

    • Operating range: 30% ~ 75%RH non-condensing

    • Storage range: < 95%RH non-condensing

  • Atmospheric pressure

    • Atmosphere pressure range when transport or storage: 500hPa ~ 1060hPa

    • Operating atmospher pressure range: 700hPa ~ 1060hPa

  • Air Flow

    • Ambient air flow: Less 1.0 m/s

  • Temperature control range with relative guideline

    • Air temperature control mode: 25~37°C

    • Skin temperature control mode: 34~37°C

    • Temperature rise time (ambient temperature 25°C): < 30 minutes

    • Temperature variability: < 1°C

    • Temperature uniformity (Mattress in lever): < 1.5°C

    • Correlation of displayed incubator temperature to actual incubator temperature at temperature equilibrium: <0.7°C

    • Skin sensor accuracy: <0.1°C

  • Alarms

    • Power Fail (Power Failure): Actuates if main AC power fails and no DC back-up power is present or switching to battery power.

    • Fan Alarms: Motor trouble or fan rotate speed less low or fan stop

    • DC Low Voltage Alarms: DC 12V or Battery supply low 10.5V or DC24V low 22.5V

    • Sensor Alarms: Actuates if there is a sensor failure or skin sensor isn't placed in right place

    • Temperature deviation alarm: Air temperature or skin temperature too high or air temperature or skin temperature too low.

    • Over-temperature alarm: Temperature too high in hood under air temperature control mode or skin temperature control mode.

    • E Rom trouble alarms: Within temp controller system trouble

  • Whole equipment physical dimensions

    • Length: 170 cm

    • Width: 50 cm

    • Incubator body weight (including 2 batteries: 80 kg

    • Stand weight: 25 kg

    • The max. force load of the IV Pole: 20N

    • The max. force load of the mattress: 98N

    • Mattress's length: 63 cm

    • Mattress's width: 35 cm

  • Other specifications

    • Noise level within the hood environment: <60dB(A)

    • With ambient of equal or less than 50Dba

    • Carbon Dioxide (CO2) Lever within the hood: Less than 0.5% when a 4% mixture of CO2 in air is delivered at 750 ml / min at a point 10 cm above the center of the mattress

    • Air flow above mattress: <0.35m/s

    • Incubator service life: Incubator's use life is limited, generally 8 years, but it is according to every incubator different using frequency, operational status and environment of working and storage. The service life will be changed.

    • Factory's Default Setting:

      • Temperature control mode: Air control mode

      • Air set temperature: 32°C

      • Skin set temp: 34°C

      • Temperature unit: °C