Model: Spot
Vital signs in seconds with hospital-grade technology that’s easy to use, accurate and affordable.
Features:
Measures noninvasive blood pressure (NIBP), pulse rate, temperature and SpO2 in about 30 seconds
IR Connectivity to Electronic Medical Records
Lightweight and portable with a variety of mounting options
All configurations include NIBP, pulse rate and MAP
Optional—SureTemp thermometry, Masimo or Nellcor pulse oximetry
Specifications:
Noninvasive Blood Pressure (NIBP)
Cuff Pressure Range: 0 to 300 mmHg
Initial Cuff Inflation: 160 mmHg (adjustable)
Systolic Range: 60 to 250 mmHg
Diastolic Range: 30 to 160 mmHg
Mean Arterial Pressure Range: 40 to 190 mmHg
Blood Pressure Accuracy: Blood pressure meets or exceeds SP10: 1992 AAMI standards
Blood Pressure Determination Time: 20 - 45 seconds typical
Overpressure Cutoff: 315 mmHg +/- 15 mmHg
Pulse Rate Range (using BP determination): 40 to 200 bpm
Pulse Rate Accuracy (using BP determination): +/- 5%
Temperature
Measurement Range: 86° F to 109.4° F (30° C to 43° C)
Calibration Accuracy: +/-0.2° F (+/- 0.1° C) Monitor Mode
Determination Time:
Oral - Approximately 4 seconds
Axillary - Approximately 10 seconds
Rectal - Approximately 15 seconds
Probe:
Oral / Axillary - Blue Cap
Rectal - Red Cap
SpO2
Performance Measurement Range : 70 - 100%
Pulse Rate Range: 25 to 240 bpm
SpO2 Accuracy: Masimo: +/- 2 digits, +/- 3 digits
Pulse Rate Accuracy: +/- 3 digits, +/- 3 digits
Mechanical
Dimensions: 9.7" x 5.7" x 4.7" ( 24.6 x 14.5 x 12.0 cm )
Weight: Approximately 4.6 lbs ( 2.1 kg )
Electrical
AC Power Supply: 7.2 V DC at 1.0 A. Rechargeable sealed lead acid internal battery
Battery Recharge Time: 90 - 100% after 12 hours. Simultaneously operates device and charges battery when AC power adapter is plugged in.
Operating Time: A fully charged battery supports 150 typical blood pressure determinations at 7 minute intervals.
Environmental
Operating Temperature: 50° F to 104° F ( 10° C to 40° C )
Operating Relative Humdity: 15 - 90% (noncondensing)
Operating Altitude: -557 ft to + 16,000 ft (-170 m to +4,877 m)
Storage Temperature: -4° F to 122° F ( -20° C to 50° C )
Storage Humidity: 15 - 90% (non-condensing)
EMC Standard: IEC / EN 60601-1-2
Warranty: Two year warranty on parts and labor