English Spanish
  Life Medical Equipment
    HomeHome  AboutAbout  ContactContact  Find usFind Us  SearchSearch
Category Listing
 Aesthetic
 Anesthesia
News and Information Blog
 Cardiology
 Defibrillators
 Diapulse Brochure
 Emergency
 Endoscopy
 Imaging
 Instrumentation
 IV Poles
 Laboratory
  Analyzers
  Balances
  Centrifuges
  Counters
  Dry Baths
  Electrophoresis
  Freeze Dryers
  Freeze Storage
  Grinders
  Histology
  Incubators
  Laminar Flow Benches
  Microbiology
  Microscopes
  Mixers
  Ovens
  Pipettes
  Plasma Extractors
  Refrigerators
  Rheometers
  Spectrophotometers
  Supplies
  Test Kits
  Timers
  Ultrasonic Cleaners
  Viewers
  Washers
  Water Baths
  Water Purification
 Lamps / Lights
 Medical Furniture
 Miscellaneous
 Neonatal
 Neurology
 OB/GYN
 Ophthalmology
 Packages
 Pain Relief Cream
 Patient Monitoring
 Pediatric
 Physical Therapy
 Pumps
 Respiratory
 Sterilizer
 Surgery
 Survey
 Vascular
 Videos
 Wound Care
 Laboratory
Buck Scientific Flame Photometer  Product Detail
Model: PFP-7

The Model PFP-7 is a low temperature, single channel flame photometer designed as a low cost approach for the routine determination of sodium and potassium. Additional filters are available for the measurement of lithium, barium, and calcium.

Features:
  • Electronic Flame Failure Sensor

  • Flame Fail Indicator

  • Switchable Decimal Point

  • Filter Wheel for fast changing analytical parameters

  • Independent Zero and Gain Controls with an Off-Set Capability on the Zero Control

  • Fine and Coarse Gain Controls

  • Built-In Push Button Electronic Ignition

  • High Resolution to 0.1 PPM

  • Universal Voltage/Frequency Operation

  • Built-In Power Sockets for Operating Recorder or Autosampler

  • Analog Recorder Output

  • Readout: L.E.D. 3½ digit

  • Range: 0-199.9

  • Working Range:

    • Na 0.50 - 10ppm Ca 3.0 - 40 ppm

    • K 0.75 - 25 ppm Ba 5.0 - 100 ppm

    • Li 0.75 - 20ppm

  • Reproducibility: 1% CV for 20 consecutive samples using 10ppm set to 100 scale reading

  • Linearity: Better than 2% when Na and K are 3 ppm, Li at 5 ppm and are set to 100 scale reading.

  • Specificity: Interference from Na, K, Li equal in conc. to test of element will be less than 0.5%

  • Recorder Output: Nominal 1.00V for a reading of 100.0