Schiller Product Detail
Model: Cardiovit AT-10 Plus
The AT-10 plus combines the basics of electrocardiography with the benefits of the IT world. It not only provides all functions of a high-quality 12-channel electrocardiograph but also meets the requirements of an integrated diagnosis workstation. Its brilliant
communication concept makes the AT-10 plus an extremely flexible tool:
- As resting ECG station in clinics and practices
- As ergometry measuring station meeting highest demands
- As ECG terminal for mobile ECG recording
- As integrated recording station in a cardiological practice
- As cardiopulmonary diagnosis station for industrial medicine
The AT-10 plus convinces by its performance, featuring:
- Compact laptop design
- High-resolution colour display (13 leads on screen)
- Integrated 12-channel ECG recorder for top quality ECGs
- Pacemaker detection
- Rechargeable battery for mobile use
- Resting ECG measurement
- XML data transfer for Resting ECG to a PC or Information System via Ethernet or internal modem
- Memory
- Bi-directional network communication provides remote access to SEMA-stored patient records
Options:
- Automatic ECG measurement and computer-aided ECG interpretation for pediatric and adult ECGs
- Thrombolysis recommendation software
- Pacemaker measurements
- Stress ECG software (fully automatic ergometry, average cycles, ST measurement, rhythm recording, detailed report)
- Spirometry
- Barcode reader
SSF & SBS Tracing Filter and Stabilizer
Ripened Filter Technique with SSF SCHILLER Smoothing Filter,SBS SCHILLER Baseline Stabilizer and SPF SCHILLER Powerline Filter
- SPF is an adaptive, digital filter that removes powerline noise from the ECG
- SSF greatly filters distortions in the resting ECG that may be caused by outside influences
- SSF allows good valuable tracing right away and eliminates therefore the need of unnecessary additional recordings
- SSF is a unique resting ECG filter which can be activated in the units AT-2plus, AT-4, AT-5, AT-10, AT-60, CS-100, CS-200
- SBS greatly filters distortions in the exercise ECG that may be caused by movements of the patient (baseline wandering)
- SBS is a unique exercise ECG filter which can be activated in the units AT-2plus, AT-10, AT-60, CS-100, CS-200
- Both filters do not change the computerized ECG interpretation, the computerized ECG measurement value table, the original QRS complexes.
- They greatly help the user to have a valuable ECG right the first time.
ECG Interpretive
SCHILLER ECG Measurement and Interpretation Software for Children and Adult ECGs
Computerized ECG measurement values greatly help the physician in her/his daily work: it saves time and the results are more accurate and consistent compared to manual calculation. SCHILLER developed its own programs. That allows us to update and improve our software and to make updates available for the physicians at any time after purchasing an equipment. The program passed extensive checking and, among others, the CSE diagnostic database. SCHILLER personnel is member of advisory ECG interpretation councils. The computerized ECG interpretation is designed to assist the physician but never replaces her/his decision. The physician has to consider all other relevant information of the patient.
- SCHILLER measurement program M provides overall measurements and a table with lead specific measurement results of all 12 simultaneously acquired standard leads for resting and exercise ECGs.
- SCHILLER interpretation program C (includes M software) gives the physician over a thousand different interpretation hints (after a Resting ECG).
- The M software is included in the standard version of the following SCHILLER units: AT-101, AT-101 easy, AT-101 Tele, AT-102, AT-10 plus, AT-104 PC, CS-200, AT-110 (and can be upgraded in the AT-1).
Schiller Communication Module (SCM)
New innovative built-in communication module for the transmission of diagnostic recordings in XML formats over the standard Internet transfer protocol HTTP
- Transmission of Resting ECG data in XML format to a PC or Information System via Ethernet interface or built-in analogue modem (optional)
- Singular or batch transmission of recordings
- Built-in DHCP client for automatic assigning of IP-addresses in a DHCP enabled network
- Efficient transmission of data via modem connections using built-in gzip compression of the recordings
- Secure transmission of patient data via the Internet is possible using built-in 1024-bit strong encryption (requires SCHILLER server-side software)
SCHILLER Filter Technology
SPF SCHILLER Powerline Filter, SSF SCHILLER Smoothing Filter, SMF SCHILLER Myogram-Filter and SBS SCHILLER Baseline Stabilizer
-
SPF SCHILLER Powerline Frequency Filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by adaptive digital filtering.
SPF can be activated in the following SCHILLER units: AT-1, AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102, AT-104 PC, AT-110 and CS-200.
- SSF SCHILLER Smoothing Filter, SMF SCHILLER Myogram Filter (muscle tremor filter): Adaptive low pass smoothing filter to suppress muscle tremor and high-frequency noise, without bothering the QRS complex.
SSF is a unique Resting ECG filter, which can be activated in the following SCHILLER units: AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102 and CS-200. SMF can be activated in the following SCHILLER units: AT-1, AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102, AT-104 PC, AT-110 and CS-200.
- SBS SCHILLER Baseline Stabilizer: Filter to suppress or greatly reduce base line fluctuations without changing the measurement values (for Resting and Exercise ECGs); safety standard: IEC/EN 60601-2-51 (protection against hazardous output).
SBS is a unique Exercise ECG filter, which can be activated in the following SCHILLER units: AT-1, AT-101, AT-101 easy, AT-101 Tele, AT-2 plus, AT-10 plus, AT-102, AT-104 PC, AT-110 and CS-200.
- All these filters do neither change the computerized ECG interpretation, the computerized ECG measurement value table nor the original QRS complexes.
- They greatly help the user to have a valuable ECG right the first time.
Request Info
|
|
Back |
|
|