Schiller Product Detail
Model: Cardiovit AT-1
The AT-1 offers a 12-lead ECG analysis in a three-channel format at a surprisingly low price. Perfect for office use, hospital bedside and ambulatory fieldwork.
Features:
-
Crisp, clear, accurate ECG tracings on 3 1/2" Z-fold thermal paper.
-
Perforated reports are ready to file.
-
Fully automatic with easy-touch keyboard and one-button operation.
-
Fast and accurate analysis using Schiller's proven measurement and interpretation program (optional).
-
Allows remote interpretation upgrade at any time.
-
Comes with a built-in rechargeable battery with low battery indicator.
-
Meets all industry standards, including AHA, ACC and AAMI.
Specifications:
- System
- Dimensions: 290 x 210 x 69 mm / 11.4 x 8.3 x 2.7 in. (l/w/h)
- Weight: Ca. 2,9 kg / approx. 6.7 lbs
- Power supply requirements: 220 - 240 V (nominal), 50/60 Hz or 110 - 115 V (nominal), 50/60 Hz independent operation with built-in rechargeable battery, LED indicator for mains and battery, built-in charger unit
- Power consumption: Max. 28 VA
- Battery charging time: 15 hrs. from a completely discharged battery, 3 hrs. to 60% capacity
- Battery capacity: 2 hrs of normal use
- Leads: Standard / Cabrera
- Patient input circuitry: Fully floating and isolated, defibrillation protected (only with original SCHILLER patient cable)
- Frequency range of digital recorder: 0 Hz to > 150 Hz (IEC/AHA)
- ECG amplifier:
- Simultaneous, synchronous registration of all 9 active electrode signals (= 12 standard leads)
- Sampling frequency: 1000 Hz
- Pacemaker detection: ≥ ± 2 mV/ ≥ ± 0.1 ms
- Myogram (muscle tremor) filter: 25 Hz (40 dB/dec) or 35 Hz (20 dB/dec), programmable
- Line frequency filter: Distortion-free suppression of superimposed 50 or 60 Hz sinusoidal interferences by means of an adaptive digital filter
- Control panel: Pad keys, LED indicators
- LED indicators:
- Lead group
- Paper tray empty or jammed
- Mains connected
- Filter status (on/off)
- Battery operation and battery
- Loose electrodes low (indicator flashes)
- Norms:
- Safety standards: IEC/EN 60601-1; UL 60601-1; C22.2 No. 601.1-M90; IEC/EN 60601-2-25; IEC/EN 60601-1-2(EMC)
- Protection Class: I according to IEC/EN 60601-1 (with internal power supply)
- Applied Part: CF according IEC/EN 60601-1
- Conformity: CE according Directive 93/42/EEC (Medical Devices)
- Classification: IIa according Directive 93/92/EEC
- Environmental conditions:
- Temperature, operating: 10° to 40° C / 50° to 104° F
- Temperature, storage: -10° to 50° C / 14° to 122° F
- Relative humidity: 25 to 95 % (non-condensing)
- Pressure, operating: 700 - 1060 hPa
- Printing (built-in thermal printer):
- Paper speed: 5 / 25 / 50 mm/s (direct)
- Sensitivity: 5 / 10 / 20 mm/mV, either automatically adjusted or manually selected
- Chart paper: Thermoreactive, Z-folded, 90 mm / 3.5 in wide, or Roll, 90 mm wide
- Printing process:
- High-resolution thermal printhead
- 8 dots per mm / 200 dots per in (amplitude axes)
- 40 dots per mm / 1000 dots per in (time axes, @ 25 mm/s)
- Recording tracks: 3 channels, positioned at optimal with on 80 mm / 3.2 in., automatic baseline adjustment
- Automatic lead programs: 3 channel representation of 12 simultaneously acquired standard leads
- Data record: With option M: ECG measurement results (intervals, amplitudes, electrical axes, average complexes with optional measurement reference markings)
- Scope of delivery:
- CARDIOVIT AT-1 basic unit with 3-channel Resting ECG with 12 simultaneous leads and pacemaker detection
- Accessories:
- 10-lead patient cable
- 1 set of electrodes, consists of 4 stainless steel extremity electrodes, 6 precodial electrodes or disposable electrodes
- Electrode gel
- Power cable
- 1 pkg. of recording paper
- Operating manual
- Cart (optional)
- Software-Options:Automatic measurement and interpretation program for resting ECGs
Request Info
|
|
Back |
|
|