Welch Allyn AED Product Detail
Model: 10
When it comes to simplicity and compact design, the Welch Allyn AED 10 is ready for rescue. With input from AED users at every level of skill, the AED 10 was designed for simple operation and quick deployment by the minimally trained or infrequent user.
Features:
-
Intuitive design - easy "1-2-3" operation.
-
Compact size -ideal for small spaces.
-
Follows American Heart Association energy protocols.
-
Comprehensive device self checks, making the AED 10 virtually maintenance-free.
-
High-resolution backlit display, easy viewing in direct sunlight or poor lighting environments.
-
Lightweight - among the lightest weight device in its class.
-
Only one lithium battery is required for years of standby performance.
-
Large internal memory.
-
Welch Allyn Orbital Biphasic Technology.
-
Wireless (IR)Communications - "beam" event data to PC or printer.
-
Battery life gauge.
Specifications:
Defibrillator
-
Output:
Welch Allyn Orbital™ Biphasic Truncated exponential.
-
Energy Select:
200, 300, 360J or user configurable among the energy options:
150, 200, 300, 360
-
Charge Time:
Less than 5 seconds to 150J, less than 15 seconds to 360J.
-
Analysis Time:
4-16 seconds.
-
Audible Prompts:
18 audible prompts.
-
Visual Prompts:
20 text screen prompts.
-
Controls:
Four buttons - On/Off, Shock, and 2 software configurable buttons.
-
Accuracy:
±10% or 1J (whichever is greater) at 50Ω.
Display
-
Size:
54 x 36 mm.
-
Type:
Backlit monochrome LCD.
-
Display Resolution:
160 x 100 pixels.
-
Low Battery Indicator:
Battery Icon gauge on display with 10 capacity levels.
-
Backlight:
LED.
Battery
-
Non-Rechargeable:
LiMnO2 12V, 2.6 Ah.
-
Capacity:
90 discharges at 360 Joules or 125 discharges at 200 Joules or 150 discharges at 150 Joules or 5 hours ECG monitoring.
-
Shelf Life:
(25°C±15°C) 10 years (5 years storage + 5 years standby); 5 years standby (after installation).
General
-
Weight:
3.5 lbs. with battery (1.6 kg.)
-
Size:
8.25" x 6.875" x 2.75" (210 x 175 x 70 mm).
-
Operating Temperature:
0° to 50°C.
-
Storage Temperature:
-30° to 70°C (without battery).
-
Humidity:
Up to 95% or 10° to 95°C (non-condensing).
-
Altitude:
Up to 15,000 feet (-150 to 4570 m).
-
Shock:
Mil Std 810E method 516.4, procedure 1 (40G, 6-9ms pulse, 1/2 sine each axis).
-
Vibration:
Mil Std 810 method 514.4, category 1.
-
Water resistance:
IEC 529 IPX4.
Drop Test:
Mil Std 810F method 516.5 Procedure IV (1 meter drop onto any edge, corner, or surface).
Electrical Isolation
-
Power:
Unit operates on internal battery only.
-
External Electrical Connections:
No external devices are attached to the unit.
-
Risk Current Category:
Class II equipment with defibrillator-proof BF type patient applied parts (as per definition of IEC 60601-1 standard.)
Electromagnetic Compatibility
-
Radiated Emissions:
EN55011; CISPR11 B
-
ESD:
EN61000-4-2; 8KV air 6KV contact.
-
Radiated Susceptibility:
EN61000-4-3 (10 V/M (20 v/m EN60601-2-4))
-
Magnetic Field Emissions:
MIL STD RE101 (AAMI DF 24.3.18.1)
-
Magnetic Field Susceptibility:
MIL STD RS101 1 Gauss, 47 Hz-1.8 KHz.
Data Management
-
Event Documentation:
Internal.
-
Internal Memory Capacity:
1MB: 250 4-sec ECG samples or 3000 time stamped events.
-
Quick Report:
Treatment Summary, Event Log, Test Log.
-
Communication:
RS-232 via Infrared (IR) port to PC or printer.
Request Info
|
|