English Spanish
  Life Medical Equipment
    HomeHome  AboutAbout  ContactContact  Find usFind Us  SearchSearch
Category Listing
 Aesthetic
 Anesthesia
News and Information Blog
 Cardiology
 Defibrillators
 Diapulse Brochure
 Emergency
 Endoscopy
 Imaging
 Instrumentation
 IV Poles
 Laboratory
  Analyzers
  Balances
  Centrifuges
  Counters
  Dry Baths
  Electrophoresis
  Freeze Dryers
  Freeze Storage
  Grinders
  Histology
  Incubators
  Laminar Flow Benches
  Microbiology
  Microscopes
  Mixers
  Ovens
  Pipettes
  Plasma Extractors
  Refrigerators
  Rheometers
  Spectrophotometers
  Supplies
  Test Kits
  Timers
  Ultrasonic Cleaners
  Viewers
  Washers
  Water Baths
  Water Purification
 Lamps / Lights
 Medical Furniture
 Miscellaneous
 Neonatal
 Neurology
 OB/GYN
 Ophthalmology
 Packages
 Pain Relief Cream
 Patient Monitoring
 Pediatric
 Physical Therapy
 Pumps
 Respiratory
 Sterilizer
 Surgery
 Survey
 Vascular
 Videos
 Wound Care
 Laboratory
HemoPoint  Product Detail
Model: H2 Photometer

Fast.
Using a single drop of blood, Stanbio’s HemoPoint® H2 offers accurate results for both hemoglobin and hematocrit (calculated) tests — in as little as ten seconds! The touch screen displays the current time, battery status and has a new battery backlight feature improving readability throughout the self prompting test procedure.

Advanced.
Utilizing proven microcuvette technology, the HemoPoint® H2 features a pr oprietary “soft load” cuvette holder to minimize blood contamination of the meter. The hemoglobin result is flagged if it is outside the user-defined limits.

Easy to Use.
The HemoPoint® H2’s user-friendly sampling technique minimizes training time and its rechargeable battery makes it completely mobile. Recall the last 4,000 test results with the touch of a button and attach an optional printer to record patient’s test results—immediately, or from stored memory!

Specifications
Methodology ................................................. Optical absorption photometry
Principle ........................................................ Azidemethemoglobin
Calibration .................................................... Factory calibrated
Sample Type ......................................... Capillary, venous, or arterial blood
Sample Size .................................................. 8 µL
Hematocrit Range ............................................ 36 - 54% (calculated)
Linearity .......................................................... 0 - 23.5 g/dL
Within Run Precision CV.................................... < 1%
Total Precision CV ........................................... < 1.2%

Request Info


Enlarged Picture
 


Back



Join the Life Medical Equipment mailing list
Email:

 7874 NW 64th Street,  Miami, Florida, 33166
Tel: (305) 594-0000 - Fax: (305) 594-2020 -
© Copyright 2007 - Life Medical Equipment International Inc.