Features:
- ECG, Respiration, ST, Arrhythmia, NIBP, SpO2, Temperature
- 12.1 inch color TFT display
- Maximum 8 channel waveform display
- 120-hour graphic and tabular trend information
- 600-group vital sign data recall
- 12-minute ECG waveform storage and review
- ST segment and arrhythmia analysis
- Pacemaker detection
- Optional cardiac output and multi-gas monitoring
-
Networking capability
- Bed to bed view
- Applications from adults to neonates
Specifications:
- ECG
- Heart Rate Range: 15-300bpm
- Lead Selection I, II, III, V, aVR, aVL, aVF
- Lead Fault Alarm Audible / Visual
- Sweep Speed 12.5 / 25 / 50mm / S
- Gain Selection x 4, x 2, x 1, x 0.5, x 0.25
- ECG Calibration 1mV software generated
- Protection Against electrosurgical interference and defibrillation
- ST Segment Analysis -0.8V to +0.8mV
- Arrhythmia Analysis 13 types of arrhythmia identification (Optional)
- ECG Waveform 4 channel
- NIBP
- Method Automatic oscillometric
- Parameters SYS / DIA / MAP
- Operating Modes Manual / Auto / Stat (5 minutes)
- Scale mmHg / kPa
- Cuff Pressure Range Adult / Child: (0-300mmHg), Neonate: (0-150mmHg)
- IBP (Optional)
- Channel: 1 or 2
- Measurement Range -30 to +300mmHg
- Resolution 1mmHg
- Sweep Speed 6.25 / 12.5 / 25mm / S ± 10%
- Transducer Sensitivity 5uV / V / mmHg
- Pulse Oximetry (SpO2)
- Display Digit, waveform, pulse
- Saturation Range 0-100% (Adult / Child / Neonate)
- Resolution 1%
- Accuracy ± 2% (70-100%), ± 3% (50-69%)
- Pulse Range 30-254bpm
- Accuracy ± 1% (30-100bpm), ± 2% (>100bpm)
- Respiration
- Method: Impedance
- Respiration Range 0-150brpm
- Accuracy ±1brpm
- Alarm User selectable alarm limits automatically kept in memory
- Respiration Lead Selection RA-LA, RA-LL, LA-RL,RL-LL
- Capnograph (CO2) (Optional)
- Range 0-99mmHg
- Accuracy ± 2mmHg (0-40mmHg), ± 5% (41-76mmHg), ± 10% (77-99mmHg)
- Resolution 1mmHg
- Respiration Range 0-150brpm ± 2brpm
- Sweep Speed 6.25 / 12.5 / 25mm / s ± 10%
- Calibration Auto
- Start-up Time <30 seconds
- Temperature (Optional)
- Channel 2
- Display T1, T2, & change in T
- Range 0-50°C
- Resolution 0.1°C
- Accuracy ±0.1°C
- Probe Skin or Esophageal / Rectal (Optional)
- Recorder (Optional)
- Recorder Type 2 / 3 channel thermal recorder
- Printing Mode Real-time or alarm triggered printing of waveform or text
- Resolution X-axis: up to 800 dpi (32 dots / mm), Y-axis: 203 dpi (8dots / mm)
- Annotation Date, time (24 hours)
- Power Requirements
- AC Input 110-230VAC, 50 / 60Hz
- Power Consumption <115VA
- Battery 12V 4AH sealed lead-acid, maintenance free
- Battery Operating Time Approx. 2 hours when fully charged
- Physical Specifications
- Net Weight 6.5kg
- Gross Weight 9kg
- Dimensions 250H x 320W x 170D(mm)
Request Info
|