Model: VSM 300
The Vital Signs Monitor 300
Series helps enhance your productivity by providing automated vital signs
before, during and after procedures. The simple, push-button menu operation and
bright display allows you to quickly learn and easily obtain the important
information you need, so you spend more time with your patients.
Features:
- Non-invasive blood
pressure monitoring
- Nellcor Motion Tolerant
Pulse Oximetry
- 4-Second SureTemp Plus
Thermometry
- Thermal Printer
- Automatic blood pressure
mode
- Separate modes for adult,
pediatric and neonatal patients
- LCD Display simplifies
menu navigation
- Bright LED display of
vital signs readings
- Displayed clock
- Programmable Alarms for
high/low systolic, diastolic and pulse rate
- Built-in memory saves up
to 99 sets of measurement data
- Simple, straightforward
operation and intuitive menu navigation
Technical
Specifications:
- Display: 16 character LCD
- Dimensions:
6.6"x10.0"x6.0" (HxWxD)
- Weight: Approximately 5.4
lbs (2.4 kg)
- Non-Invasive Blood
Pressure (NIBP)
- Cuff Pressure Range: 0
to 270 mmHg, 0 to 36 kPa
- Initial Cuff
Inflation: Adult 160 mmHg (21.3 kPa), Pediatric 120 mmHg (16 kPa),
Neonate 90mmHg (12kPa)
- Systolic Range: Adult
30 to 260 mmHg (4 to 34.5 kPa), Pediatric 30 to 160 mmHg (4 to 21.3 kPa),
Neonate 25 to 120 mmHg (3.3 to 16 kPa)
- Diastolic Range: Adult
20 to 235 mmHg (2.7 to 31.3 kPa), Pediatric 15 to 130 mmHg (2 to 17.3
kPa), Neonate 10 to 105 mmHg (1.3 to 14 kPa)
- MAP: Adult 20 to 255
mmHg (2.7 to 30 kPa), Pediatric 15 to 140 mmHg (2 to 18.7 kPa), Neonate
10 to 110 mmHg (1.3 to 14.7 kPa)
- Blood pressure
measurement meets or exceeds ANSI/AAMI SP10:2002
- Pulse Rate Range: 30
to 220 bpm, Pulse Rate Accuracy: ± 3 bpm or 3%
- Pulse Oximetry (SpO2)
- Saturation Range: 1%
to 100%
- Accuracy:
Adult/Pediatric 70-100% ±2 digits, Neonate 70-100% ±3 digits
- Pulse Rate Range: 20
to 255 bpm
- Pulse Rate Accuracy:
- ±2 bpm (without
motion)
- ±3 bpm (with
motion)
- ±3 digits (low
perfusion)
- Temperature
- Measurement Range: 80F
to 110F (26.7C to 43.3C)
- Calibration Accuracy:
± 0.2F (±0.1C); meets or exceeds ASTME1112-00; EN12470-3:2000
- Determination Time
(approximate):
- Predictive
- Oral: 4-6
seconds
- Pediatric
Axillary: 10-13 seconds
- Adult Axillary:
12-15 seconds
- Rectal: 10-13
seconds
- Monitored
- Oral/Rectal: 3
minutes
- Axillary: 5
minutes
- Printer: Thermal Transfer
Printer
- Power
- AC Power supply: 8
volts DC and 0.75 amperes
- Rechargeable sealed
lead acid internal battery
- Operating time: 8
hours
- Battery recharge time:
90% in 12 hours
- Simultaneously
operates monitor and charges battery when AC power adapter is plugged in
Request Info