English
Spanish
Home
About
Contact
Find Us
Search
Category Listing
Aesthetic
Anesthesia
Blog
Cardiology
Defibrillators
Diapulse Brochure
Emergency
Endoscopy
Imaging
Instrumentation
IV Poles
Laboratory
Lamps / Lights
Medical Furniture
Miscellaneous
Neonatal
Neurology
OB/GYN
Ophthalmology
Packages
Pain Relief Cream
Patient Monitoring
CO2 and Agent
Multiparameter
NIBP
Pulse Oximeters
Sphygmomanometer
Pediatric
Physical Therapy
Pumps
Respiratory
Sterilizer
Surgery
Survey
Vascular
Videos
Wound Care
Patient Monitoring
Seti Compact Monitor Product Detail
Features
High resolution 6.5" monochrome LCD display
24 hours data storage facility in graphical mode with zoom facility and separate tabular trend for 100 NIBP readings
NIBP with three modes: Manual, Automatic, STAT
Graded and color coded audio/visual alarms
Alarm recall facility to view last 16 critical alarms (patient related)
Rechargeable battery backup
External battery jack (12V) for car battery - Transport application
Can be used as transport and ambulatory monitor
Suitable for neonate, pediatric, and adult applications
Optional Printer
FDA 510 (K)
Non-Invasive Blood Pressure
Oscillometric Principle, Display of Systolic, Diastolic and Mean pressure
Modes: Manual, STAT (5 min continuous), Automatic (interval 2 to 90 minutes).
Range: 20 to 255 mmHg
Auto Zero: Zero Pressure Reference is automatically established after every reading
Cuffs: Quick Connect / Disconnect
Safety Features: Automatic deflation if - pressure exceeds 300 mmHg for adult and 150 mmHg for neonate - Measurement time exceeds 180 seconds (adult) 90 seconds (neonate) - microprocessor failure.
Alarm limits: Selectable for systolic and diastolic.
Range: 20-250 + mmHg
Accuracy: +/- 3 mmHg
Pulse Oximetry
Pitch variation with change in oxygen saturation
SpO2 range: 0-100%
Display of pulse strength, plethysmograph, PR and SpO2 values.
Display of perfusion on bar graph.
Accuracy: 100 to 70% (+/- 2 digits), 69 to 50% (+/-3 digits), 49 to 0% (unspecified). Accuracy in neonatal monitoring 100 to 70% (+/- 3 digits).
Modes: Normal and Fast Response
Alarms:
Low 50-95%
High 55-100%
Alarms
Alarm setting for all parameters.
Patient alarm: RED flashing with audio and message indicator.
Equipment alarm: YELLOW flashing with audio and message indicator. Alarm auto-set facility provided. Auto setting of alarm for PR and SpO2.
Manual settings: Systolic and Diastolic
Alarm Recall: Last 16 critical alarms with time and date
Volume Control: 4 levels of volume
Trends
24 hours of Graphical and Tabular Trend fo rHR/PR, SpO2
NIBP trend: Last 100 readings (tabular)
Alarm Recall: Last 16 alarm events with date, time and message. 2 hour zoom for graphical trends with mark, record and print facility.
Time Scale: 12 Hour (resolution of 3 minutes) and 2 hour (resolution of 30 sec) for graphical trend).
Recording
Optional in-built dual channel thermal recorder for recording two waveforms (selectable) with numerical data and alarm status.
NIBP and tabular trend recording with patient information.
Direct / Delayed / Continuous modes of recording.
Record On Alarm facility (selectable).
Speed: 25 mm/sec or 50 mm/sec.
General
Dimensions: 145 x 220 x 185 mm
Weight: 3.5 kg with in-built battery and recorder.
Power Supply
Universal power supply: 95-265V AC, 50/60 Hz
Power ratings: 40 Watt
Battery type: 14.8V, 14.4Ah (Li-ION)
Operating time: 4 hours on fully charged battery (with full load & NIBP auto mode 2 minutes interval and recorder on for 2 minutes.)
Charging time: 100% charge in 6 hr. for fully discharged battery.
External battery: 12V DC input
Display
Resolution: 640 x 480 pixels
Type: Color
Size: 6.4"
Back Panel
VGA output
Mains power on/off
RS-232 output
Ground Connection
External Printer Port
Trace Speed
12.5, 25, or 50 mm/sec for ECG and SpO2
Request Info
Enlarged Picture
Back
Join the
Life Medical Equipment
mailing list
Email:
7874 NW 64th Street, Miami, Florida, 33166
Tel: (305) 594-0000
- Fax: (305) 594-2020 -
© Copyright 2007 - Life Medical Equipment International Inc.