Welch Allyn  Product Detail
Model: Spot

Vital signs in seconds with hospital-grade technology that’s easy to use, accurate and affordable.

Features:
  • Measures noninvasive blood pressure (NIBP), pulse rate, temperature and SpO2 in about 30 seconds

  • IR Connectivity to Electronic Medical Records

  • Lightweight and portable with a variety of mounting options

  • All configurations include NIBP, pulse rate and MAP

  • Optional—SureTemp thermometry, Masimo or Nellcor pulse oximetry

Specifications:
  • Noninvasive Blood Pressure (NIBP)

    • Cuff Pressure Range: 0 to 300 mmHg

    • Initial Cuff Inflation: 160 mmHg (adjustable)

    • Systolic Range: 60 to 250 mmHg

    • Diastolic Range: 30 to 160 mmHg

    • Mean Arterial Pressure Range: 40 to 190 mmHg

    • Blood Pressure Accuracy: Blood pressure meets or exceeds SP10: 1992 AAMI standards

    • Blood Pressure Determination Time: 20 - 45 seconds typical

    • Overpressure Cutoff: 315 mmHg +/- 15 mmHg

    • Pulse Rate Range (using BP determination): 40 to 200 bpm

    • Pulse Rate Accuracy (using BP determination): +/- 5%

  • Temperature

    • Measurement Range: 86° F to 109.4° F (30° C to 43° C)

    • Calibration Accuracy: +/-0.2° F (+/- 0.1° C) Monitor Mode

    • Determination Time:

      • Oral - Approximately 4 seconds

      • Axillary - Approximately 10 seconds

      • Rectal - Approximately 15 seconds

    • Probe:

      • Oral / Axillary - Blue Cap

      • Rectal - Red Cap

  • SpO2

    • Performance Measurement Range : 70 - 100%

    • Pulse Rate Range: 25 to 240 bpm

    • SpO2 Accuracy: Masimo: +/- 2 digits, +/- 3 digits

    • Pulse Rate Accuracy: +/- 3 digits, +/- 3 digits

  • Mechanical

    • Dimensions: 9.7" x 5.7" x 4.7" ( 24.6 x 14.5 x 12.0 cm )

    • Weight: Approximately 4.6 lbs ( 2.1 kg )

  • Electrical

    • AC Power Supply: 7.2 V DC at 1.0 A. Rechargeable sealed lead acid internal battery

    • Battery Recharge Time: 90 - 100% after 12 hours. Simultaneously operates device and charges battery when AC power adapter is plugged in.

    • Operating Time: A fully charged battery supports 150 typical blood pressure determinations at 7 minute intervals.

  • Environmental

    • Operating Temperature: 50° F to 104° F ( 10° C to 40° C )

    • Operating Relative Humdity: 15 - 90% (noncondensing)

    • Operating Altitude: -557 ft to + 16,000 ft (-170 m to +4,877 m)

    • Storage Temperature: -4° F to 122° F ( -20° C to 50° C )

    • Storage Humidity: 15 - 90% (non-condensing)

    • EMC Standard: IEC / EN 60601-1-2

  • Warranty: Two year warranty on parts and labor



Request Info