 Patient Monitoring
Datascope  Product Detail
Model: Spectrum O.R.

Spectrum OR comes to you with a long history of reliability and success.

Built on the well-known Passport 2 and Spectrum platforms, Spectrum OR offers an advanced monitoring system that incorporates the things that make monitoring easier - optimal display visibility, quick-access menus, one-touch function keys, and multiple trend capabilities. For a more complete anesthesia monitoring package, Spectrum OR offers MAC, Bispectral Index and Spirometry measurement options. Designed for scalability, Spectrum OR enables you to easily adjust your monitoring capabilities for each case. Developed exclusively for the Operating Room, it delivers the features you need with the dependability and flexibility you’ve come to expect. Paired with the Gas Module SE, Spectrum OR is a robust, yet user-friendly monitoring system created specifically with you in mind. Why take a chance? Choose the monitoring solution with a proven track record – choose Spectrum OR.

Features:
  • Built-in, vivid 12.1-inch display with auto-adjustable large numerics and waveforms for optimal visibility.

  • Optional remote color display suitable for screen expansion at the anesthesia workstation or in the PACU. Also ideal for use as a secondary, surgical display.

  • Includes the standard functions you need for peri-anesthesia monitoring including 3 or 5-lead ECG, non-invasive blood pressure, Masimo SET motion tolerant SpO2, temperature, and drug calculations.

  • Offers various options to best meet your department’s needs including Microstream CO2, BISx Module, Nellcor OxiMax SpO2, cardiac output, continuous cardiac output/SvO2, invasive blood pressures, ST and arrhythmia analysis and more

  • Drug calculations package minimizes manual effort by performing automatic calculations of the most commonly used IV medications

  • Cardiac output, pulmonary artery wedge pressure, and comprehensive hemodynamic calculations provide the tools needed for advanced cardiac monitoring

  • External Parameter Module offers cost-effective options for your more complex cases including cardiac output, extra invasive blood pressures and temperature

  • BISx Module provides Bispectral Index data, a useful indicator of a patient’s level of consciousness during anesthesia

  • Integrates to the Gas Module SE for breath-by-breath measurement of Fast O2, CO2, and N2O with automatic 5-agent identification. Provides real-time display of all critical inspired and expired gases on a highly reliable platform

  • Optional Spirometry Module available with Gas Module SE provides real-time measurement and display of patient pressures, volumes and graphical loops for optimal patient ventilation

Specifications:
  • Display

    • Size: 12.1-inch (30.7cm) Color Active Matrix TFT LCD

    • Resolution: 800 x 600 pixels

    • Waveforms: 3 to 8

  • ECG (3-Lead and 5-Lead)

    • Leads: I, II, III, aVR, aVL, aVF, V

    • Cable Detection: Autodetecting Datascope 3 or 5 wire

    • Display Sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0, cm/mV ± 10%

    • Frequency Response To Screen

      • Extended Mode: 0.05 – 100 Hz, -3db

      • Monitor Mode: 0.5 – 40 Hz, -3db

      • ST Mode: 0.05 – 40 Hz, -3db

    • ECG Sync Pulse for Cardioversion:

      • Delay: 35 ms max between QRS Peak and rising edge of Sync Pulse

      • Amplitude: 2Vp minimum into a 5k ohm load

      • Width: 2-7 ms

    • Analog Output: (ECG)

      • Delay: 25 ms max

      • Sensitivity: 1 V/mV of input, ± 10%

    • Defibrillator Overload Protection: Withstand 360 Joule discharge as per IEC 60601-2-27, 51.101.1

    • Recovery Time: Time for recovery to within 1mV in < 8 seconds automatically. 3 seconds from 1Vpp at 60 Hz

  • Heart Rate Meter

    • Range: 30 – 300 BPM Adult/Pediatric, 30 – 350 BPM Neonate 3-lead and 5-lead / 30-300 BMP 12-lead

    • Accuracy: ± 3 BPM or ± 3% at 30 – 250 BPM whichever is greater, ± 5% at 251 – 350 BPM

    • Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV and duration 0.1 to 2 ms with no tail. AAMI EC-13-1992 4.1.4 (3-Lead and 5-Lead) Rejects all pulses of amplitude ± 2.0 mV to 700 mV and duration 0.1 to 2 ms with 100 ms time constant tail of less than 2.0 mV, or 4 ms time constant tail of < 2.0 mV per AAMI EC-13-1992 3.1.4.2.

    • Tall T-Wave Rejection: Rejects all T-Waves of amplitude less than 120% of 1 mV, 100 ms QRS, T wave duration of 180 ms and Q-T interval of 350 ms per AAMI EC-13-1992 4.1.2.1 (c)

  • ST Analysis

    • 3-lead or 5-lead Range: -9.9 mm to +9.9 mm

    • Resolution: 0.1 mm

    • Default ST Measuring Point: 80 ms after j point for HR <120 BPM, 60 ms after j point for HR >120 BPM

  • Arrhythmia Analysis

    • 3-lead or 5-lead cables: Adult / Pediatric Only: Asystole, Irregular Heart Rate, Couplets, Bigeminy, Trigeminy, Ventricular Tachycardia, Ventricular Fibrillation, PVC’s per minute, Runs, Ventricular Rhythm

  • Respiration (ECG)

    • Range: 4 to 199 BPM

    • Accuracy: ± 2% or 2 breaths per minute whichever is greater from 4 to 150 BPM, ± 4% from 151 to 199 BPM

    • Lead: I or II

  • Non-Invasive Blood Pressure

    • Technique: Oscillometric

    • Systolic Range: Adult: 55 - 235 mmHg, Pediatric: 55 - 160 mmHg, Neonate: 45 - 120 mmHg

    • Diastolic Range: Adult: 30 - 200 mmHg, Pediatric: 30 - 150 mmHg, Neonate: 20 - 100 mmHg

    • Systolic Accuracy: Mean Error less than ± 5 mmHg, standard deviation less than ± 8 mmHg

    • Diastolic Accuracy: Mean Error less than ± 5 mmHg, standard deviation less than ± 8 mmHg

    • Pulse Rate Range: Adult/Pediatric: 35 to 245 BPM, Neonate: 70 to 245 BPM

    • Pulse Rate Accuracy: ±3 BPM or 3% whichever is greater

    • Connector Type: Rectus

    • Cuff Inflation: Volume of 500 cc to 300 mmHg in 35 sec

  • Temperature

    • Scale: Selectable C or F

    • Range: 15 to 45C / 59 to 113F (T1 and T2) 0C to 5.5C / 0F to 9.9F (Delta T)

    • Accuracy: ± 0.1C (15C to 45C) exclusive of probe errors. ± 0.2F (59F to 113F) exclusive of probe errors.

  • Pulse Oximetry

    • Masimo SET SpO2 Accuracy Saturation with no motion conditions

      • Adult/Pediatric: 70% to 100% ± 2 digits SpO2, 0 to 69% unspecified

      • Neonate: 70% to 100% ± 3 digits SpO2, 0 to 69% unspecified

      • Ear Sensor (Adult/Pediatric): 70% to 100% ± 4 digits SpO2, 0 to 69% unspecified

    • Masimo SET SpO2 Accuracy Saturation during motion conditions

      • Adult/Pediatric/Neonate: 70% to 100% ± 3 digits SpO2

      • Response Time: 18 seconds to 95% of final step of % SpO2 value from 60-95% at 75 BPM. Averaging set at 8 seconds.

    • Pulse Rate Range Masimo with no motion conditions

      • Adult/Pediatric/Neonate: 30-235 ±3 BPM, Ear Sensor (Adult/Pediatric) 30-235 ± 3 BPM

    • Pulse Rate Range Masimo during motion conditions

      • Adult/Pediatric/Neonate: 30-235 ±5 BPM

    • Low Perfusion Performance

      • Masimo: > 0.02% Pulse Amplitude and % Transmission > 5% / Saturation (%SpO2) ± 2 digits; Pulse ± 3 digits

    • Nellcor OxiMax SpO2 Saturation Accuracy

      • Adult/Pediatric/Neonate: 70% to 100% ± 3 digits

    • Pulse Rate Range Nellcor: 20-249 ±3 BPM

  • IBP

    • Range: Sys/Dia/Mean -30 to +300 mmHg

    • Accuracy: ± 2 mmHg or 2% whichever is greater

    • Scale: -10 to 10, 0-20, 0-40, 0-160, 0-225, 0-320, 60-140 mmHg

    • Zero Range: ± 120 mmHg

    • Excitation: 5V DC ± 2%

    • Frequency Response: DC to 16 Hz ± 1Hz, -3db

  • Recorder

    • Speed: 3.125, 6.25, 12.5, 25 mm, and 50 mm/sec. Note: 3.125 speed is for CO2/Resp only.

  • CO2 (Microstream)

    • Range: 0 – 99 mmHg

    • Accuracy: 0 – 38 mmHg ± 2 mmHg 39 – 99 mmHg ± 5% + .08% for every 1mmHg above 40 mmHg (> 20 min)

    • Respiration Rate: 0-150 breaths per minute

    • Respiration Accuracy: ± 1 breath per minute from 0 – 40 BPM. ± 2 BPM from 41– 70 BPM. ± 3% from 71 – 100 BPM. ± 5% from 101 – 150 BPM

    • CO2 Waveform Recognition: 5 mmHg ± 2 mmHg bandwidth

    • Start-up Time: 30 seconds typical

    • Sampling Rate: 50 ml/min ± 7.5 ml/min

    • Auto Zero: <15 seconds at 5, 10, 15 and 60 minutes, then every 60 minutes thereafter.

  • Electrical Ratings

    • AC Voltage: 100 – 240 VAC ± 10%, 50/60 Hz ± 3 Hz

    • Battery Type: Sealed Lead Acid

    • Number of Batteries: 2

    • Battery Voltage: 12 V

    • Battery Capacity: 2.3 Ah

    • Battery Run Time: 1 hour, 20 min from two fully charged, new batteries at 25C with ECG, SpO2 and NIBP running at 15 minutes intervals

    • Recharge Time: 16 hrs max

  • Environmental Conditions

    • Storage Temperature: -20C to + 60C/-4F to +140F

    • Storage Humidity: 10 – 95% non-condensing

    • Operating Altitude: -381 to 3,014 metres ASL, 1060hPa to 700hPa, 795 mmHg to 525 mmHg

    • Operating Temperature: 5C to 40C/41F to 104F

    • Operating Humidity: 15% to 95%, non-condensing

  • Physical Dimensions

    • Monitor Size:

      • 26.7cm H x 30.2cm W x 18.8cm D, 10.5" H x 11.9" W x 7.4" D without module

      • 27.2cm H x 30.2cm W x 18.8cm D, 10.7" H x 11.9" W x 7.5" D with module

    • Weight:

      • 5.43 kg (11.95 lbs) without optional accessories

      • 7.04 kg (15.52 lbs) with 2 batteries, without optional accessories

      • 0.8 kg (1.75 lbs) module, without optional accessories

  • Cardiac Output

    • Range: 0.2 to 20.0 liters/min

    • C.O. Repeatability: + 2% or 0.02 l/min from the mean value

    • Blood Temp Range: 17.5°C to 43°C (63.5°F to 109.4°F)

    • Blood Temp Accuracy: + 0.2°C (± 0.4°F) exclusive of probe errors

    • Injectate Temp Range: -1.0°C to 30.0°C (30.0°F to 86°F )

    • Injectate Temp Accuracy: ± 0.2°C (±0.4°F )exclusive of probe errors

  • BIS (Bispectral Index)

    • Bispectral Index (BIS) Range: 0 - 99

    • Signal Quality Index (SQI) Range: 0 - 100%

    • EMG Range: 30 - 80dB

    • Suppression Ratio (SR): 0 - 100%

    • Burst Count: 0 - 30

    • Input Impedance: >50 Mohm

    • Noise (RTI): <0.3uV RMS 0.25 - 50 Hz

    • Input Range: +/- 1mV

    • EEG Bandwidth: 0.25 - 100Hz (-3dB)

    • Filters (On):

      • High Pass: 2.0 Hz (-3dB).

      • Low Pass: 70 Hz (-3dB)

      • Notch: 50 Hz and 60 Hz

    • Filters (Off)

      • High Pass: 0.25 Hz (-3dB)

      • Low Pass: None

      • Notch: None

  • Agency Compliances

      This monitor complies with the following industry standards:

    • Safety: IEC 60601-1:1988 + A1:1991 + A2:1995, UL 60601-1:2003, CSA Standard C22.2, No. 601.1M90, EN60601-1-1:2001/IEC 60601-1-1:2000/, IEC 60601-1-2:Ed. 2.1, EN60601-1-4:1996 + A1:1999/IEC 60601-1-4:1996 + A1:1999, EN 60601-2-30:2000 / IEC 601-2-30:1999, EN 60601-2-34:2000 / IEC 60601-2-34:2000, EN 60601-2-49:2001/IEC 60601-2-49:2001, EN60601-2-25:1993/IEC 60601-2-25:1993 + A1:1999, section 36.202.101, EN 60601-2-27:1994 / IEC 60601-2-27:1994, EN 60601-2-26:2003/IEC 60601-2-26:2002

    • Hazard: EN ISO 14971:2000 + A1:2003

    • Performance: EN/ISO 21647:2004, EN ISO 9919:2005/ISO 9919:2005, EN 1060-1:1995 + A1:2002, EN 1060-3:1997 + A1:2005, AAMI EC13:1992, AAMI EC11:1991, ISO 3744:1994, ANSI/AAMI/ISO 10993-10:1995, ANSI/AAMI/ISO 10993-1:1995, AAMI SP10:1996, IEC 60601-1-8:2005

    • Environmental: IEC 60068-2-6:1995 + Corrigendum 1, IEC 60068-2-27:1987, IEC 60068-2-64:1994 + Corrigendum 1, EN60529:1991 + A1:2001 + Corrigendum 1,EN 55011:1998 + A1:1999 + A2:2002 (CISPR 11), EN 61000-3-2:2000 + A1:2001 + A2:2005, EN 61000-3-3:1995 + A1:2001 + A2:2005, EN 61000-4-6:2003 + A1:2004 + A2:2006, EN 61000-4-3:2006, EN 61000-4-8:1993 + A1:2001, EN 61000-4-2:1995 + A1:1998 + A2:2001, EN 61000-4-4:2004, IEC 61000-4-5:2005, EN 61000-4-11:2004, ECRI PB-296892:1979 (for Drop and Impact requirements only), ISTA: 1994 procedure 1A, 2002/96/EC:2003