Hewlett-Packard  Product Detail
Model: Codemaster XL

  • Defibrillator with ECG and recorder

  • Provides 1-2-3 operation

  • Built-in pediatric paddles under slide-off adult paddles

  • Preset heart rate alarms

  • High-capacity battery

  • Built-in diagnostics

  • Dimensions: 7.9" x 11.8" x 15.6" (20cm x 30cm x 39.7cm)

  • Weight: 24 lbs. / 10.9kg

  • Battery:

    • Type: Rechargeable, sealed lead-acid battery. 4 Ah, 12 V nominal.

    • Charge Time: 2 hours to 90% of full capacity. 18 hours to 100% capacity. Repeated charging to less than 100% will reduce the useful life of the battery.

    • Capacity: 2.5 hours monitoring or 50 full-energy discharges or 1 hour monitoring and recording.

    • AC input: 100 to 230 VAC +/- 15%, 50/60 Hz.

    • Battery Indicators: Illuminated LED indicates battery is charging. Low Battery message appears on the monitor.

  • Defibrillator

    • Waveform: damped sinusoidal.

    • Output energy (delivered): 2,3,5,7,10,20,30,50,70,100,150,200,300, and 360 joules.

    • Charge control: push-button on apex paddle and on front panel.

    • Charge time: less than 5 seconds to 360 joules with a functional battery installed.

    • Charge done indicator: display indicates available energy, charge-done light on apex paddle, charge done tone.

    • Synchronizer: SYNC message appears on the monitor and is annoted periodically on the recorder while in synchronous mode. An audible beep sounds with each detected R-wave, while a marker on the monitor and sync mark on the recorder strip indicate the discharge point.

    • Paddles: standard paddles are anterior / anterior. Adult electrodes (83 cm sq) slide off to expose pediatric electrodes (21 cm sq). Paddle cord is 10 feet (3m). Full range of internal paddles are available.

  • Monitor

    • Input: ECG activity may be viewed through the paddles or patient cable.

    • Lead fault: LEADS OFF message and dashed baseline appear on the monitor if a lead becomes disconnected. Common mode rejection: greater than 100dB measured as per AAMI standards for cardiac monitors.

    • Heart rate display: digital read out on monitor from 20 to 280 bpm.

  • Recorder

    • Annotations: time, date, heart rate, event markers, ECG mode, and selected energy.

    • Recorder Mode: automatically documents events and ECG during defibrillation episodes. The recorder can be configured to run in either real time or with a 6-second delay.

    • Frequency response: .5 to 40Hz monitor bandwidth. .05 to 150 Hz diagnostic bandwidth is selectable.

Request Info